10 SETTING UP AN EXPERIMENT
CUSTOMIZING DATA COLLECTION
2. Touch Periodic.
3. Touch OK.
Putting the SPARK into manual sampling mode
In manual sampling mode, a single value from each measurement is recorded
each time you manually trigger the SPARK. Complete these steps to put the
SPARK into manual sampling mode:
1. Touch the Sampling Options button.
The Sampling Options screen opens.
2. Touch Manual.
3. Touch OK.
Setting an automatic stop condition
When a stop condition is set, the SPARK automatically stops recording data
after a set time interval. Complete these steps to set a stop condition:
1. Touch the Sampling Options button.
The Sampling Options screen opens.
2. Under Automatic Stop Condition, touch the Condition: box and
select Stop after duration.
3. Touch the Value: box and enter a time value.
4. Touch the Units: box and select units of time.
5. Touch OK.